What this topic covers

Safety, a subject area of the PSI bulletin for the Texas air conditioning and refrigeration contractor exams (no subtopics are published): lockout/tagout, ladders, refrigerant and pressure safety, personal protective equipment and carbon monoxide. These are original practice notes, not materials of the TDLR or PSI. OSHA rules are described from the texts in force on January 1, 2027, citing the general industry standard (29 CFR 1910) and the construction standard (29 CFR 1926) as such; field safety uses standard practices of the trade. The exam is open book: know where to look in your authorized references for each requirement, rather than memorizing it.

Lockout/tagout (29 CFR 1910.147)

Ladders (29 CFR 1926.1053)

Pressure testing gases

Refrigerant hazards

PPE and carbon monoxide

Take the free test · full question bank and mock exams with a subscription

Sample questions (5)

1. Under 29 CFR 1910.147, who normally removes a lockout device from an energy isolating device once the service work is finished?

  1. The supervisor who assigned the service call
  2. The authorized employee who applied that device
  3. Any authorized employee working in the same crew
  4. The building owner's designated representative

29 CFR 1910.147(e)(3) requires each lockout or tagout device to be removed by the employee who applied it. The only exception is a documented employer procedure used when that employee is not available, so a supervisor, a crew member, or an owner's representative may not remove a lock as a routine matter.

2. A technician has locked out every energy isolating device on a rooftop unit and relieved the stored energy. Under 29 CFR 1910.147, what must the technician do before starting work?

  1. Verify that the unit is isolated and deenergized
  2. Notify affected employees that the locks were removed
  3. Inspect the work area for nonessential items
  4. Replace each lock with a tag so the unit can restart

29 CFR 1910.147(d)(6) requires the authorized employee to verify isolation and deenergization before starting work on locked-out equipment. Inspecting the work area for nonessential items is a release step under 1910.147(e)(1), and notifying affected employees that the devices were removed comes under 1910.147(e)(2)(ii), after removal and before restart. Nothing in paragraph (d) calls for swapping locks for tags so the unit can restart.

3. Under 29 CFR 1926.1053, a non-self-supporting portable ladder must be set so that the horizontal distance from the top support to its foot is approximately what fraction of the ladder's working length?

  1. One-eighth
  2. Three-quarters
  3. One-half
  4. One-quarter

29 CFR 1926.1053(b)(5)(i) requires a non-self-supporting ladder to be used at an angle where the horizontal distance from the top support to the foot is approximately one-quarter of the working length, measured along the ladder between the foot and the top support. One-eighth would set the ladder too steep, while one-half and three-quarters would lean it far too flat and invite the base to slide out.

4. Which practice is NOT permitted by 29 CFR 1926.1053 when a technician works from a stepladder?

  1. Locking the metal spreader before climbing the ladder
  2. Standing on the top step of the stepladder as a step
  3. Using nonconductive side rails near exposed live parts
  4. Tagging a ladder with a broken rung as Do Not Use

29 CFR 1926.1053(b)(13) states that the top or top step of a stepladder shall not be used as a step. The other practices follow the rule: 1926.1053(a)(8) requires a metal spreader or locking device to hold a stepladder open, 1926.1053(b)(12) requires nonconductive side rails where the ladder could contact exposed energized equipment, and 1926.1053(b)(16) has a ladder with a defect such as a broken rung tagged Do Not Use or marked, and withdrawn from service.

5. A technician will pressure test a new refrigerant circuit from a cylinder fitted with a pressure regulator and a relief device. Which gas should be used?

  1. Pure oxygen from a cylinder
  2. Acetylene from a cylinder
  3. Compressed air from a shop line
  4. Dry nitrogen from a cylinder

Dry nitrogen is inert and is the standard test gas when supplied through a regulator with a relief device. Oxygen can ignite violently on contact with oil, acetylene is a fuel gas that becomes unstable under pressure, and shop air carries moisture and oxygen that contaminate the system and add a fire risk.